APLIKASI OVERCURRENT RELAY UNTUK PROTEKSI ARUS LEBIH

  • Ilham Anshoruddin Politeknik Perkapalan Negeri Surabaya
  • Mohammad Basuki Rahmat Politeknik Perkapalan Negeri Surabaya
  • Catur Rakhmad Handoko Politeknik Perkapalan Negeri Surabaya
  • Hendro Agus Widodo Politeknik Perkapalan Negeri Surabaya
Keywords: Evaluasi, Overcurrent Relay, Proteksi, Standar British BS 142, Standar IEC 60255

Abstract

ABSTRAKBandara merupakan bangunan dan peralatan yang menunjang kelengkapan untuk menjamin tersedianya fasilitas bagi angkutan udara. Bandara merupakan objek vital yang harus tersuplai listrik setiap saat. Oleh karena itu, membutuhkan sistem kelistrikan yang handal dan kontinyu agar seluruh kegiatan penerbangan berjalan dengan baik. Untuk mewujudkan hal tersebut, maka dilaksanakan evaluasi proteksi kelistrikan. Evaluasi dilaksanakan dengan menganalisis perbandingan antara data aktual Overcurrent Relay dengan perhitungan sesuai standar IEC 60255 dan British BS 142. Melalui hasil analisis yang telah dilaksanakan, terdapat beberapa kekurangan dari setting relai pada penyetelan pick up dan grading time. Berdasarkan hasil plot kurva pada Gambar 4.6, setelan pickup relai 9 masih dibawah full load ampere yaitu dengan penyetelan 115A. Pick up ini belum sesuai Standart BS 142 yaitu 1,05 x FLA < Iset < 1,3 x FLA. Setelah dilakukan analisis, berdasarkan nilai full load ampere 144,3A diperoleh setelan pick up 154,5A. Sedangkan grading time antara relai 7 dan relai 9 masih terlalu sempit yaitu 0,15s. Menurut Standar IEC 60255, grading time minimum adalah 0,2s, jadi grading time antara relai 7 dan relai 9 harus diatur kembali dengan penyetelan minimum 0,2s.

ABSTRACT - Airports are the buildings and equipment that support completeness to ensure the availability of facilities for air transport. Airports are vital objects which must be well supplied electricity at all times. Therefore, it requires a reliable electricity system and continuously so that the entire aviation activities go well. To realize this, conducted the evaluation of electrical protection. The evaluation was conducted by analyzing the ratio between the actual data of overcurrent relays with the calculation according to the standard IEC 60255 and British BS 142. Through the results of the analysis that has been carried out, there are some drawbacks of setting relays on setting a pick up and grading time. Based on the results of the plot curves in Figure 4.6, the pickup setting of relay 9 is still under full load ampere by setting 115A. Pick up is not in accordance Standard BS 142 is 1.05 x FLA <Iset <1.3 x FLA. After the analysis, based on the values of full load ampere 144,3A obtained 154,5A of pick up settings. While grading time between relays 7 and the relay 9 is still too narrow namely 0,15s. According to IEC Standard 60255, a minimum grading time is 0,2s, so grading time between 7 and relays 9 relays must be set back to the minimum setting 0,2s

Published
2019-12-18