DESAIN DAN PEMODELAN STORAGE TANK KAPASITAS 40.000 kL MENGGUNAKAN SOFTWARE INTEGRAPH TANK

  • yoga pangestu haris
  • prasojo budi
  • eko prayitno muhamad muhadi
Keywords: API 650, annular bottom, Integraph TANK, roof, Shell, Tank

Abstract

Abstract - Storage tank is one important component in the petroleum industry which acts as one of a component to make the fuel storage process of the oil run well before being distrubuted. The distribution area is wide it needs to perform an anticipation to prevent running out of fuel oil stock. To prevent the out of stock of fuel oil, then it is neccesary to add a new storage tank. The standards used for this tank design are theAPI 650, 2016, Twelfth Edition, Addendum 2. Calculation methods for plate thickness using one foot method include shell, bottom plate, annular bottom plate and roof. Standard used for the fire prevention system is the  NFPA 11 and 15. For cathodic protection using the NACE standard. From the result of this study, its obtained minimum thickness shell result of the shell plate, bottom plate, annular bottom plateandroofplate.Stability of the tank is resulted in a stable tank without the need for anchorage. The cathodic protection in the tank using the SACP method with a magnesium anode. Find out the foam, water and cooling requirement  for fire prevention  on the tank. Find out the cost of construction for the tank.

Published
2018-12-07